MH6.6 / MH8.6 HYDRAULICS 5-49 Tank channel – preloading valves Description The return oil from the tank channel of the control block must flow back to the hydraulic reservoir through the parallel non-return valves in port T1 and in port T2. To open the valves, the valve pop- pets must be pushed backwards against the spring forces. As far as the valve in T2 is concerned, the cooler flow resistance must be added to these forces. This outflow resistance generates the preloading pressure in the tank channel. The amount of the preloading pressure is also determined by the re- turn-flow volume.
A large volume of oil requires a great drain cross-section, which means that the valve poppet must open further so that the spring under the poppet is compressed more strongly. Fig. 3 This preloading pressure ensures the oil supply of the cylinders and the travel oil motor via the re- plenishing non-return valves. Tank channel The non-return valve in T1 is equipped with a 5-bar spring whereas the valve in T2 is equipped with a 2-bar spring. The amount of return oil drained through the valve in T2, must overcome the force of the 2-bar spring plus the viscosity-dependent cooler flow resis- tance.
When the oil is cold, the overall resistance is higher and part of the volume is drained through the 5-bar valve in T1. The cooling oil volume is regulated by the differential resistances in T1 and in T2 depending on viscosity. reguliert. The 5-bar valve in T1 protects in addition the radia- tor against inadmissibly high pressures. The by-pass bore, parallel to the valve in T2, serves as a pressure relief for the tank channel after engine stop. Fig. 4 Carefully read personal and machine SAFETY INSTRUCTIONS (at the beginning of this manual)