MH6.6 / MH8.6 HYDRAULICS 5-51 Proportional valves for control spool adjustment Description The proportional valves for bilateral spool adjust- ment are located in the same housing. They serve the purpose of converting the electrical control current from the ESX into a pilot control pressure. Y20Xa Y20Xb The pilot control pressure is available at port P and at both proportional valves only after a cylinder or a travel function has been initiated. If the valve with identification letter a is energized, the pilot control pressure passes into the upper cap. The control spool would be moved down- wards.

The valve with identification letter b lets pilot pres- sure flow into the lower cap with the control spool- being adjusted upwards. Any movement of the joysticks or of the pedals is detected by the ESX which sends a lever- or pedal-dependent control current to the correspond- ing proportional valve. Symbol In neutral position of all control elements, both pilot control caps are linked with the leakage oil channel L via the control pistons in the proportional valves. Leakage oil then flows pressureless back to the reservoir. After activation of the ignition and after booting of the electronic system, a PWM signal of approx.

100 mA is present at the solenoids even without a function being actuated to detect possible faults as, for instance, a broken cable or a short-circuit to ground. Fig. 7 Carefully read personal and machine SAFETY INSTRUCTIONS (at the beginning of this manual)