MH6.6 / MH8.6 HYDRAULICS 5-55 Description The pilot-control circuit supplies oil to the pilot- control unit with the solenoid valves of the pump control, the load-limit regulation and the circuit elements of the superstructure and undercarriage control. Solenoid valve Y35 of the superstructure holding brake is without current so that the multiple-disk brake is blocked by spring force. Solenoid valve Y35 is controlled from the ESX. Pilot-control circuit in neutral position Solenoid valve Y290 of the pilot-control pressure shutoff is without current. The pilot-control pump supplies oil to the pilot- control unit which comprises the pressure-limiting devices.

The ESX actuates solenoid valve Y290 when the travel pedal is de- pressed. Pilot-control pressure is available at the proportional valves of the travel control spool only after the travel pedal has been de- pressed. The pilot-control pressure limited in this way gets to port Y3 of the variable displacement pump, ad- justing both pumps towards Vgmin, but not to zero flow, as both pumps receive a small amount of load-sensing pressure via the pump control propor- tional valves Y241 and Y242 at ports X1. The pumps swivel out to such an extent that each pump sends a flow of flushing oil through the con- trol block.

This is achieved by ESX activation of proportional valves Y241 and Y242 when the con- trol elements are in neutral position. Solenoid valve Y63 of the power assist function is actuated by the central electronic control unit CU. When the valve is without current, the power assist function is not operational. Proportional valve Y10 of the load-limit regulation is activated with high current from load-limit regula- tor A10, with maximum control pressure getting to both pump regulators via port X3. This maximum control pressure reduces the power consumption of pumps 1 and 2 to minimum.

The nitrogen accumulator at port S supplies the pilot-control system after an engine stop to permit depressurization of the hydraulic system or emer- gency lowering of the equipment. For this purpose, the ignition must be on and the control unit must be booted so that the corresponding solenoids can be actuated and the pilot-control pressure get to the control block. Solenoid valve Y113 of the pilot-control pressure shut-off for the working and slewing functions is without current, even after actuation of the pilot- control pressure lever in the left-hand control con- sole.

The controlled non-return valve under the accumu- lator works as a pressure-holding valve as the accumulated pressure drops quickly when the en- gine has been stopped. The ESX actuates solenoid valve Y113 only after a control lever has been moved out of neutral position. This means that pilot-control pres- sure is available at the proportional valves of the control block and at the proportional valves of the slew- ing pump only after a working func- tion has been activated. Port A serves to supply control block (105) of the undercarriage control. Carefully read personal and machine SAFETY INSTRUCTIONS (at the beginning of this manual)