MH MH6.6/MH8.6 — GB COPERTINA.fm

5-58 HYDRAULICS MH6.6 / MH8.6 Solenoid valves and their functions Proportional valve Y10 of the load-limit regulator Control edge Control edge Fig. 2 Key P Pilot-control pressure A3 Control pressure to power regulator L Tank connection, pressureless 1 Valve housing 2 Solenoid 3 Plunger 4 Control piston 5 Spring plate 6 Compensator spring 7 Emergency control Fig. 1 Description Proportional valve Y 10 is used as a signal con- verter. The valve converts electric control current from the load-limit regulator into control pressure for the output regulation of the working pumps. The control pressure is proportional to the control current.

The flow cross-section at the control edge of the control piston is open as long as the magnetic force is higher. As long as the control edge is open, the control pressure increases and the re- setting forces increase as well. The control edge is closed when the forces are in equilibrium. The valve housing (1) accomodates solenoid (2), plunger (3) and control piston (4) with spring plate (5) and adjusting spring (6). When less current flows through the solenoid, the resetting forces press the control piston into a position creating a drainage cross-section towards the tank. Through this opening, the control pres- sure is reduced.

The drainage cross-section closes after the equilibrium of forces has been reestablished. When current flows through the solenoid, the magnetic force displaces the plunger and the con- trol piston against the force of the spring. The control edge of the control piston opens a cross- section through which the pilot pressure can partly pass to port A3 as control pressure. Emergency control The control pressure thus generated builds up a spring-assisted resetting force which displaces the control piston backwards against the magnetic force of the solenoid.

In the event of an electronic failure, the propor- tional valve is equipped with a mechanical emer- gency control device (7) with which control piston (4) can be adjusted to maintain the machine func- tions. In the emergency mode, the machine can be operated at reduced speed. Carefully read personal and machine SAFETY INSTRUCTIONS (at the beginning of this manual)