MH MH6.6/MH8.6 — GB COPERTINA.fm

MH6.6 / MH8.6 HYDRAULICS 5-95 Priority valve (Nos. 44) Control edge Fig. 6 Fig. 4 Description Symbol The priority valve is used in conjunction with steer- ing valves in closed-center load-sensing design. P 7 bar The valve divides the discharge flow and directs the two partial flows to the steering system and the fan drive with the steering system having priority. LS The priority valve works like a three-way flow con- trol valve with the regulated flow (CF) being made available to the steering system and the remaining flow (EF) to the fan drive. Neutral The discharge flow is admitted to both sides of the control piston via metering orifices.

In neutral posi- tion, the load-signal line (LS) is connected via the non-return valve in the steering valve with the re- sevoir. Fig. 5 Key The control spool is displaced against the die 7-bar spring so that the oil now flows via port EF to the fan drive. P Pump CF Steering (control flow) Steering EF Fan drive (excess flow) During steering, the control piston is positioned by the regulating forces in such a way that its control edge maintains a pressure differential via the me- tering orifice in steering valve (40). LS Load signal Carefully read personal and machine SAFETY INSTRUCTIONS (at the beginning of this manual) EF CF