MH MH6.6/MH8.6 — GB COPERTINA.fm

MH6.6 / MH8.6 HYDRAULICS 5-117 Description Bucket cylinder extension The description is based on the schematic dia- gram and the section drawing of the control spool. When the function is activated, proportional valve Y204a is energized by the ESX and pilot pressure gets into the lower cap. The control spool moves downwards against the spring assembly. The circuit for the bucket cylinders is fed by pump 1 and pump 2. The combination of the oil flows (double admission) is only used when the bucket is actuated alone.

Channels C1 and C2 are closed and the oil from both pumps must flow via the load-holding valves (1) into the P channel (bridging channel) and past the control edge to port A4 and on to the piston side of the bucket cylinder. When a second function is activated at the same time, the bucket cylinder receives only the flow from one pump. The oil returning from the rod side flows through the adjustable restrictor non-return valve (206) and the control block port B4 to the tank channel. Neutral In neutral position of the control spool, the flushing oil amounts from pump 1 and pump 2 flow past the control spool to the C1 and C2 channels and then past the other control spools into the tank channel.

Bucket cylinder retraction During retraction of the bucket cylinder, propor- tional valve Y204b is energized by the ESX and the pilot pressure is admitted to the lower cap. The control spool moves upwards against the spring. The circulating pressure opens both load-holding valves (1) so that the oil flow from pump 1 and the flow from pump 2 are combined in channel P (bridging channel). The oil flows through port B4 and restrictor non- return valve (206) to the rod side of the bucket cylinder. The non-return valves of the bucket parallel circuit (2) are equally opened by the circulating pressure of the pumps. The oil returning from the piston side flows through port A4 into the tank channel.

The pressure generated by the tank channel pre- loading valves is available via replenishing non- return valves, which are part of the secondary valves (3+4), on both sides of the bucket cylinder to prevent cavitation. Activation of a function The activation of a bucket function is detected by the ESX. Virtual pressure switch DSL opens be- fore the movement begins. The ESX opens the solenoid valve Y113 in the pilot-control unit (60) so that the pilot pressure gets to proportional valves Y204a and Y204b through an inlet filter in control block port PV.

The ESX energizes also proportional valves Y241 and Y242 of the pump control to admit load- sensing pressure to the pump regulators at port X1. Carefully read personal and machine SAFETY INSTRUCTIONS (at the beginning of this manual)