MH6.6 / MH8.6 HYDRAULICS 5-123 Description General lowering of stick The description is based on the schematic dia- gram and the section drawing of the control spool. During lowering of the stick, proportional valve Y205a is energized and load-sensing pressure is admitted to the upper cap. The pilot pressure moreover unblocks the check valve in port B5. The stick cylinder circuit is fed by pump 1 and pump 2. The combined oil flows (double admis- sion) act in both cylinder directions. The control spool moves downwards and the transverse bore in the hollow piston opens the passage to rod side channel B5.
The oil returning from the cylinder rod side flows through the trans- verse duct into the axial center bore of the control spool and reaches the lower non-return valve (1) and the upper preloading valve (2). When a further cylinder is activated at the same time, the stick cylinder receives only the oil flow from one pump. Neutral In neutral position, the flushing oil amounts from both pumps flow past the control spool to the C1 and C2 channels and then past the other control spools into the tank channel. The circulating pres- sure opens both load-holding valves (1) so that the oil flows from both pumps are combined in channel P.
The piston side connection A5 of the cylinder is filled with oil from both pumps via the P channel. Pressureless lowering of stick As long as the stick has not reached the ground during lowering, piston side A5 is virtually without pressure. The oil returning from the rod side which is preloaded in the center bore by non-return valve (2) opens the lower non-return valve (1), flows through the transverse duct and fills piston side A5 of the stick cylinder together with the oil flows from the pumps. The greater oil volume on the piston side causes the stick to sink faster.
At the same time, the staggered transverse ducts in the control spool throttle the return flow from the rod sides in such a way that any uncontrolled swinging of the stick caused by cavitation is avoided. The secondary valves protect the cylinder on both sides and the lines against pressure peaks. The tank channel preloading pressure is available via the replenishing non-return valves to both cylinder sides to prevent cavitation. Activation of a function Any activation of a function is detected by the ESX. The virtual pressure switch DSL in the ESX opens before the movement starts.
The ESX opens the solenoid valve Y113 in the pilot-control unit (60) so that the pilot pressure gets to propor- tional valves Y205a and Y205b through the inlet filter in port PV. The ESX energizes also propor- tional valves Y241 and Y242 of the pump control to admit load-sensing pressure to the pump regu- lators at port X1. Lowering the stick with pressure, excavat- ing tool penetrates into the ground When the bucket rests on the ground, the pres- sure on the piston side A5 rises because of the resistance offered by the ground. This pressure is admitted to the lower non-return valve (1) on the spring side. The valve closes against the preload- ing pressure in the center bore.
The oil returning from rod side B5 must now flow completely via preloading valve (2) to the tank channel. Extending the stick Proportional valve Y205b is energized by the ESX and pilot pressure gets into the lower cap and moves the control spool upwards against the spring. The control edges close the C1 and C2 channels and the oil from both pumps must flow via the load-holding valves into the P channel and past the open control edge to port B5. The oil flow opens the controlled check valve in port B5 and passes to the rod side of the stick cylinder. The return oil flows via port A3 into the tank channel.
Carefully read personal and machine SAFETY INSTRUCTIONS (at the beginning of this manual)