MH6.6 / MH8.6 HYDRAULICS 5-139 Description For this combination of cylinder functions, the fig- ure represents the oil flows of pump 1 and pump 2. The oil from pump 2 flows through the pressure compensator into the PZ channel and past the open control edge of the adjusting spool to port A6-Rf and to the adjusting cylinder. The load pres- sure generated is admitted to the pressure com- pensator as load-sensing pressure. The compen- sator supplies a regulated pressure which is avail- able through the orifice of the control spool edge as load-pressure-independent discharge flow to the adjusting cylinder.
The pilot pressure is available via port PV at the proportional valves for control spool adjustment. In the example chosen, the ESX energizes the pro- portional valves Y203b, Y204b, Y205b and Y206b whereby the pilot pressure gets into the lower caps and displaces the control spools upwards. The oil from pump 1 flows through channel P01 to the boom cylinder control spool and then via the load-holding valve into channel P past the control edge through the boom check valve to port B3-Kf and on to the boom cylinders. Channel C1 is closed by the control edge so that the downstream control spool for the bucket cylinder receives no oil from channel P01.
The load pressure oil of the adjusting cylinder flows also through the PLS channel and the shuttle valve to the relief valve and supports opening of the spring. The oil flow from pump 2 is admitted to the relief valve at the input side. The load pressure building up in the boom circuit also gets into parallel channel P1 where the bucket parallel valve is installed. The relief valve opens when the pressure of pump 2 has overcome the load pressure and the spring force at the other end. The oil from pump 2 thus pressurized flows through the by-pass channel behind the adjusting spool and into channel C2 and on to the displaced stick control spool.
Its con- trol edge closes channel P02 and the partial amount of oil from pump 2 flows via the load- holding valve into the P channel. The oil then flows past the open control edge through the check valve to port B5-Rf and to the stick cylinder. Since the control spool of the bucket is at the up- per end, a partial amount of oil from pump 1 flows with the boom load pressure through the bucket parallel valve. The load-holding valves are closed and the oil flows past the control edge to port B4- Rf and on to the bucket cylinder. The partial oil flow to the bucket cylinder depends on the restrictor orifice in the bucket parallel valve and the load pressure in the boom circuit.
The preloaded oil from pump 2 also flows through channel P2 to the second bucket parallel valve. The higher of the load pressures from pump 1 or from pump 2 prevails at the bucket parallel valves and gets to the bucket cylinder. If the load pres- sures are the same value, partial volumes from both circuits flow into the bucket cylinder. The oil flow from pump 2 gets into channel P2 and through the blanking plate into channel P02. Channel P02 is closed by the control edge at the adjusting spool. As a result, it is possible to control four simultane- ously actuated cylinder functions almost independ- ently of one another with only two pump circuits.
Carefully read personal and machine SAFETY INSTRUCTIONS (at the beginning of this manual)