MH6.6 / MH8.6 HYDRAULICS 5-145 Hammer circuit with auxiliary function like shears or crusher with boom adjusting equipment, description When the hammer is controlled by means of the pedal, proportional valve Y207a receives partial flows displacing the control spool downwards in proportion to pedal excursion. The description is based on the schematic dia- gram and the section drawing of the control spool. The load pressure building up during hammer operation gets through the load-pressure tap in the control spool into the PLS channel. The load pressure passes through orifice Ш 0.8 to the pres- sure compensator and to the electrical pressure cut-off valve Y239.2.
The circuit is supplied from pump 2. The hammer circuit comprises a pressure compensator com- bined with an electrical pressure cut-off function. For shears operation, only the compensator is used. Neutral Performance setting The hammer pressures preselected on the display unit influence the electrical pressure cut-off valve Y239.2 in such a way that the different currents limit the load-sensing pressures accordingly. This means that the pressure compensator is fed with presettable LS pressures so that it can make pre- defined regulated pressures available to the PZ channel (bridging channel) and the control spool.
In neutral position of the control spool, the oil from pump 2 flows through channel P2 to the pressure compensator and then into channel P02 past the hammer/shears control spool and via the other control spools to the tank channel. Activating the hammer To activate the hammer, depress the rocker switch. The control unit activates power stages 6 or 7, the pedal is switched over to hammer opera- tion and the hammer symbol appears on display together with a number representing the selected hammer performance level. Solenoid valve Y39.9 moreover connects the hammer return line auto- matically with the hydraulic reservoir.
The discharge flows preselected on the display unit are transmitted by the ESX to the CAN bus as reference values which are passed on by the load-limit regulator to proportional valve Y207a. The resulting pilot pressures produce variable control spool strokes and opening cross sections at the control spool edges.. Starting the hammer operation with joy- stick pushbutton or pedal At the same time, the ESX transmits the corre- sponding current signal to proportional valve Y242 so that pump 2 can meet the oil demands. The ESX detects the hammer operation and switches on solenoid valve Y113 in the pilot- control unit so that pilot pressure gets to the con- trol block via port PV.
Sensor B239 at the MS port is necessary for cali- bration purposes. Oil flow The ESX energizes proportional valves Y241 and Y242 for pump control and load-sensing pressure is admitted to both pump regulators. The preset discharge flow passes via the control spool opening cross-section to port B7 and then to the hydraulic hammer. The oil returning from the hammer flows to ham- mer by-pass valve (90) port HR, through the unlocked non-return valve and via port C to the return-flow filter in the hydraulic reservoir. Pump 1 needs load-sensing pres- sure for the cooling circuit.
The non-return valve in control spool (7) prevents the tank channel preloading pressure from escap- ing through hammer by-pass valve (90). For the same reason, the pressure-limiting valve at port A7 is not equipped with a replenishing non-retrun valve. If the pushbutton for continuous hammer opera- tion is pressed, the ESX transmits the reference value over the CAN bus and the load-limit regula- tor energizes proportional valve Y207a, whereby the control spool performs its maximum downward stroke. Carefully read personal and machine SAFETY INSTRUCTIONS (at the beginning of this manual)