MH6.6 / MH8.6 HYDRAULICS 5-159 Hammer circuit with auxiliary function like shears or crusher with monoblock equip- ment, description The load pressure building up during hammer operation gets through the load-pressure tap in the control spool into the PLS channel. The load pressure passes through orifice Ш 0.8 to the pres- sure compensator and to the electrical pressure cut-off valve Y239.2. The description is based on the schematic dia- gram and the section drawing of the control spool. The circuit is supplied from pump 2. The hammer circuit comprises a pressure compensator com- bined with an electrical pressure cut-off function. For shears operation, only the compensator is used.
Performance setting The hammer pressures preselected on the display unit influence the electrical pressure cut-off valve Y239.2 via the ESX in such a way that the differ- ent currents limit the load-sensing pressures ac- cordingly. This means that the pressure compen- sator is fed with presettable LS pressures so that it can make predefined regulated pressures avail- able to the PZ channel (bridging channel) and the control spool. Neutral In neutral position of the control spool, the oil from pump 2 flows through channel P2 to the pressure compensator and then into channel P02 past the hammer/shears control spool and via the other control spools to the tank channel.
Activating the hammer The discharge flows preselected on the display unit are transmitted by the ESX to proportional valve Y206a. The resulting pilot pressures pro- duce variable control spool strokes and opening cross sections at the control spool edges. To activate the hammer, depress the rocker switch. The control unit activates power stages 6 or 7, the pedal is switched over to hammer opera- tion and the hammer symbol appears on display together with a number representing the selected hammer performance level. Solenoid valve Y39.9 moreover connects the hammer return line auto- matically with the hydraulic reservoir.
At the same time, the ESX transmits the corre- sponding current signal to proportional valve Y242 so that pump 2 can meet the oil demands. The LS pressure signal is also transmitted to sen- sor B239 at the MS port. The current signal from the sensor is evaluated by the ESX and used for monitoring of the LS pressure. The ESX responds to a pressure drop in the LS channel by increasing the control current to proportional valve Y242 so that pump 2 delivers a higher discharge flow.
Starting the hammer operation with joy- stick pushbutton or pedal The ESX detects the hammer operation and switches on solenoid valve Y113 in the pilot- control unit so that pilot pressure gets to the con- trol block via port PV. The ESX energizes proportional valves Y241 and Y242 for pump control and load-sensing pressure is admitted to both pump regulators Oil flow The oil flows through the opening cross-section in the control spool to port B6 and then to the hy- draulic hammer. NOTE: Pump 1 needs load-sensing pressure to supply the cooling circuit.
The oil returning from the hammer flows to ham- mer by-pass valve (90) port HR, through the unlocked non-return valve and via port C to the return-flow filter in the hydraulic reservoir. If the pushbutton for continuous hammer opera- tion is pressed, the ESX control current flows to proportional valve Y206a, whereby the control spool performs its maximum downward stroke. The non-return valve in control spool (7) prevents the tank channel preloading pressure from escap- ing through hammer by-pass valve (90). For the same reason, the pressure-limiting valve at port A6 is not equipped with a replenishing non-retrun valve.
When the hammer is controlled by means of the pedal, proportional valve Y206a receives partial flows displacing the control spool downwards in proportion to pedal excursion. Carefully read personal and machine SAFETY INSTRUCTIONS (at the beginning of this manual)