MH6.6 / MH8.6 CALIBRATION 6-7 This menu is used for the calibration of propor- tional and control valves, hydraulic pumps and electric and hydraulic motors and combustion en- gines. The individual calibration categories can be se- lected with the arrow UP [ ] or with the arrow DOWN [ ] key. After confirming the selection with the SET key you are asked whether you want to perform the calibration confirmed "START CALIBRATION" or "DEFAULT". Setting of calibration parameters In the operation mode, press an arrow key until "SERVICE" appears in the lower part of the dis- play or until the service symbol is highlighted by by a frame and press the SET key.

After confirming the selection "START CALI- BRATION" with the SET key, the calibration pro- cedure is performed. The calibration procedure can be aborted at any time by pressing the arrow UP [ ] key. After the abortion, the message "CALIBRATION ABORTED" is displayed with the program returning after 3 seconds to the next higher menu. Enter the four-digit code with the arrow keys and the SET key and confirm the entered code once again with the SET key. To go back to the "SERVICE" menu, press the arrow UP [ ] or the arrow DOWN [ ] key until the start or the end of the display selection is reached.

If scrolling is continued on reaching the start or the end, the program goes back to next higher menu. Return is automatic, if the keys are not pressed for a longer period. After corresponding selection and confirmation with the SET key, the display shows the mes- sage "CALIBRATION ONGOING". After pressing the SET key = Exit, the program returns to the next higher menu. Further calibra- tion categories can then be selected and exe- cuted. Please contact our Service dept., if you are not authorized to change settings. After confirmation of the password (code), the display now offers the following four selections:

To get back to the next higher menu, press the arrow UP [ ] or the arrow DOWN [ ] key until the start or the end of the display selection is reached. - OPERATING HOURS - MAINTENANCE - CALIB. (ENGINE ON) - CALIB. (ENGINE OFF) - OPTIONS - ERROR RESET Using the arrow keys, move the frame to the "CALIB. (ENGINE ON)" bar and confirm your se- lection with the SET key. The "CALIB. (ENGINE ON)" menu offers the follow- ing five selections: - VDO - POWER - MAIN VALVE - TRAVEL - PUMP DEMAND - SWING PUMP - AUX. PRESS. Carefully read personal and machine SAFETY INSTRUCTIONS (at the beginning of this manual)