MH MH6.6/MH8.6 — GB COPERTINA.fm

MH6.6 / MH8.6 CALIBRATION 6-21 AUXILIARY EQUIPMENT PRESSURE This menu item is used for calibrating the load pressure for the attachment. After confirming the AUX. PRESS. selection with the SET key, the display offers two selections: START CALIBRATION and DEFAULT. The individual steps are executed automatically one after another. After the calibration, the program returns automatically to the next higher menu. Carefully read personal and machine SAFETY INSTRUCTIONS (at the beginning of this manual) Step Display text Remarks 1 START CALIBRATION 2 Safety lever to bottom position 1 Move safety lever (72) downwards, electro- hydraulic pilot control ON.

3 Close bucket Move joystick (69) to the left (fill bucket) 4 Hold joystick in max. position 5 Calibration prepare measuring 6 Measure at test point pressure xxx bars 7 Next step 8 Calibration prepare measuring 9 Measure at test point pressure xxx bars 10 Calibration successfully completed 11 Joysticks and pedals in neutral position 12 Safety lever in top position 0 Move safety lever (72) to position 0, electro- hydraulic pilot-control OFF Step Display text Remarks 1 DEFAULT 2 Restore default data Successfully completed