MH MH6.6/MH8.6 — GB COPERTINA.fm

MH6.6 / MH8.6 TROUBLESHOOTING AND REPAIR 7-1 FAULT CODES General information on fault codes The following units of the machine are permanently monitored: - Central Unit (CU) - Power-Control-System (PCS) - Electro-Hydraulic Controller (ESX) In the event of a fault, a fault code (e.g. N°7004) is diplayed in the upper half of the multi-function display (108, Fig. 1) in combination with two col- oured warning lights (112 yellow and 113 red, Fig. 1) which will light up individually or together, depending on the type of fault. Depending on the severity of the fault, a special tone signal will be heard in addition. Fig.

1 In addition to the fault code, the lower half of the multi-function display (108, Fig. 1) gives an expla- nation of the fault code (error text). Meaning of signals: In individual cases there is the possibility of several faults occurring at the same time. The corresponding error codes are then displayed one after another in alternation with the normal display contents. (see also "Multi-function display") Carefully read personal and machine SAFETY INSTRUCTIONS (at the beginning of this manual) RED + CONTINUOUS TONE Severe fault The safety of persons and/or the functioning of essential units of the machine is at risk. Severe faults must be rectified immediately. Shut off the machine at once.

YELLOW + SINGLE BEEP The fault signalled is not relevant to the safety of persons or to the functioning of the machine. These faults must be rectified as fast as possible. In most of the cases, however, the machine re- mains fully functional.