8-4 REPAIR INSTRUCTIONS MH6.6 / MH8.6 Hydraulic and Lubricating System Conversions or Modifications on the Machine When handling oils, greases and other chemical substances, the safety requirements that apply to the product are to be complied with. Not necessary but uncovered holes, pipe and hose unions are to be closed in a compression-proof man- ner. Fill the collected hydraulic oil into the hydraulic system only through the return pipe filter. Dispose not reused oils in a way correct from an environmental point of view. Observe the sequence of the work- ing operations when mounting or replacing components or outfits. It was defined and tried by experi- enced specialists.
In case of operations, in particular on the electric system, in which tools, spare parts, etc. may come in touch with electric lines, the battery main switch must be turned in the position “OFF”. Damaged, mechanically pre-loaded units must be completely replaced. Do not open! Or in exceptional cases only when the system and the work- ing cycle is known with precision. The technical handbook contains no information in this respect. At the operating temperature of the machine, when the operating fluids have the same temperature at least, take suitable measures to prevent burns and scalds. Caution when handling acids. Also a splash of acid can cause eye and skin injuries.
Do not smoke when handling flam- mable liquids. Caution with fire and open light. Not only fuel but also other operating fluids have often low flash points and can lightly ignite. Arbitrary conversions or modifica- tions on the hydraulic excavator are not permitted due to safety reasons. Also the nominal pressure of the pressure limiting valves must not be changed. Do not remove lead seals from the pressure limiting valves and hydrau- lic accumulators. Reinstatement into Service Before reinstating into service: - lubricate all lubricating points, - test all oil levels, if necessary cor- rect them, - carry out a functional test of the repaired components.
Test all functions of the excavator including braking in test run and release the hydraulic excavator for the reinstatement into service only if it runs in all its functions without objections. Carefully read personal and machine SAFETY INSTRUCTIONS (at the beginning of this manual)