8-6 REPAIR INSTRUCTIONS MH6.6 / MH8.6 Welding operations Welding operations Prior to any welding opera- tions on the machine: Never perform welding operations unless you are qualified to do so. - Disconnect battery by disconnect- ing first negative pole terminal, then positive pole terminal Observe the accident prevention re- gulations. - Disconnect positive pole terminal at three-phase alternator (genera- tor) Any work on receptacles that con- tain or have contained substances - that are combustible or encourage combustion, - Detach corresponding terminals and plugs from the electronic con- trol units (read and observe: “Pro- tecting electronic control units dur- ing welding operations“).
- that are susceptible to explosion or - that may develop health-hazardous gases, vapours, mist or dust dur- ing welding operations - Protect disconnected terminals and plugs from short-circuiting and soiling by covering them with foil or adhesive tape. must be carried out only under ex- pert supervision and only by ex- perienced persons authorized to do such work. Attach the welding-current pincers in the immediate vicinity of the welding zone. Systems and units (e.g. piping, radi- ator, hydraulic tank, compressed-air reservoir) must be depressurized prior to being opened.
Never connect the grounding ter- minal of the welding equipment with electronic components or with the attachment points of these compo- nents. Detailed information on the correct execution of welding operations is given in the Technical Manual "Welding for maintenance and re- pair". It is not advisable to carry out weld- ing operations on the engine or on components mounted on the en- gine, as this may damage the com- ponents. Should you have any problems or queries, apply to our service depart- ment. If parts of the machine have to be dismantled, read and observe the following sections:
The welding current must not flow via the ball-bearing slewing ring or via pin couplings, articulated joints or hydraulic cylinders. "Installing attachments, safety in- structions", "Inspection and servicing, safety in- structions", On completion of the welding oper- ation, restore all electrical connec- tions. "Repair, safety instructions". When reconnecting the battery, con- nect first the positive pole terminal, then the negative pole terminal. Carefully read personal and machine SAFETY INSTRUCTIONS (at the beginning of this manual)