8-10 REPAIR INSTRUCTIONS MH6.6 / MH8.6 3 rd point (ESX) The ESX is located to the right below the cab, be- side the slewing ring. The grounding cable (3, Fig. 7) is located to the right beside the ESX. - Unscrew base plate. - Disconnect grounding cable between frame and cab/platform plate (Fig. 6), insulating the ground- ing cable in such a way that no ground connec- tion can be inadvertently restored. Fig. 6 - Withdraw arresting lever (1, Fig. 7) at plug for- ward, and withdraw plug (2) parallel from the control unit. Removed electronic modules (PCS, ESX) must be stored at least 10 to 15 m away from the welding point.
The greater the distance to the weld- ing point, the lower the adverse ef- fects of electromagnet fields. Never store the components on the ma- chine or in the cab. Once all working steps have been executed, weld- ing operations can be carried out on the machine (read and observe: “Welding operations – safety instructions“ and “Welding instructions“). Fig. 7 On completion of the welding operation, reconnect all plug and grounding connections by performing the steps listed above in the reverse sequence. Failure to observe this procedure will rule out any liability and war- ranty coverage for resulting dam- age.