MH MH6.6/MH8.6 — GB COPERTINA.fm

MH6.6 / MH8.6 REPAIR INSTRUCTIONS 8-29 Load-limit regulator Preparations - Withdraw the connector by pulling locking lever (1) away from the connector and by pulling out connector (2) upwards from the PCS unit. The front extension of the connector must be disen- gaged. - Secure the machine as described under 'Secur- ing the machine'. - Shut off the engine and the ignition. Removing the load-limit regulator Fig. 1 Fig. 3 - Detach the step (4) behind the cab (Fig. 2) by loosening and removing the screws (5). - Loosen the nuts fixing the load-limit regulator and lift the regulator out of the electronics com- partment.

Refitting the load-limit regulator - To refit the load-limit regulator, perform the above working steps in reverse order. Fig. 2 - Remove the cover of the electronics compart- ment at the rear of the cab. Carefully read personal and machine SAFETY INSTRUCTIONS (at the beginning of this manual)