B3.9, B4.5, B5.9 Industrial Alternator Section A - Adjustment, Repair, and Replacement Page A-3 Preparatory Steps Batteries can emit explosive gases. To reduce the possibility of personal injury, always ventilate the compartment before servicing the batteries. To reduce the possibility of arcing, remove the negative (-) battery cable first and attach the negative (-) battery cable last. WARNING Disconnect the ground cable from the battery terminal. Remove the drive belt from the alternator pulley. Remove Remove and tag all wires. Complete the following steps. Remove the alternator link capscrew. Remove the alternator mounting capscrew. Remove the alternator.