Cummins — 4021389

B3.9, B4.5, B5.9 Industrial Starting Motor Section A - Adjustment, Repair, and Replacement Page A-9 Install Service Tip: If difficulty is experienced installing the drive belt (the belt seems too short), position the belt over the grooved pulleys first; then, while holding the tensioner up, slide the belt over the water pump pulley. Lift the tensioner, and install the belt. Install the four capscrews, fan, and spacer. Torque Value: 43 N•m [ 32 ft-lb ] Torque Value: 24 N•m [ 212 in-lb ] Starting Motor Preparatory Steps WARNING Batteries can emit explosive gases. To reduce the possibility of personal injury, always ventilate the compartment before servicing the batteries.

To reduce the possibility of arcing, remove the negative (-) battery cable first and attach the negative (-) battery cable last. Disconnect the ground cable from the battery terminal. Identify each electrical wire with a tag indicating location. Remove Remove the battery cable from the solenoid. Remove all other wires connected to the starter.