Cummins — 4021389

Troubleshooting Symptoms Charts B3.9, B4.5, B5.9 Industrial Page TS-58 Section TS - Troubleshooting Symptoms Lubricating Oil Sludge in the Crankcase Excessive Cause Correction Check the bulk oil supply. Drain the oil and replace with noncontaminated oil. Replace the oil filter(s). Refer to Procedure 007-002 (Lubricating Oil and Filters) in Section 5. Use the oil recommended in Procedure 018-003 (Lubricating Oil Recommendations and Specifications in Section V. STEP 1 Bulk oil supply is contaminated ............. OK Go To Next Step STEP 2 Coolant temperature is below specification ............. Refer to the Coolant Temperature Below Normal symptom tree.

OK Go To Next Step STEP 3 Crankcase ventilation system is plugged ............. Check and clean the crankcase breather and vent tube. Refer to Procedure 003-018 (Crankcase Breather Tube) in Section 3. OK Go To Next Step STEP 4 Fuel grade is not correct for the application or the Operate the engine from a tank of high-quality fuel. Refer to Procedure 018-002 (Fuel Recommendations and Specifications) in Section V. fuel quality is poor ............. OK Go To Next Step Change the oil and filters. Refer to Procedure 007-002 (Lubricating Oil and Filters) in Section 5. Use the oil recommended in Procedure 018-003 (Lubricating Oil Recommendations and Specifications) in Section V.

STEP 5 Lubricating oil does not meet specifications for ............. operating conditions OK Go To Next Step STEP 6 Contact a Cummins® Authorized Repair Facility