Cummins — 4021389

B3.9, B4.5, B5.9 Industrial Coolant Recommendations and Specifications Section V - Maintenance Specifications Page V-15 Fully formulated antifreeze must be mixed with good- quality water at a 50/50 ratio (40- to 60-percent working range). A 50/50 mixture of antifreeze and water gives a -36°C [-33°F] freezing point and a 108°C [226°F] boiling point, which is adequate for locations in North America. The actual lowest freezing point of ethylene glycol antifreeze is at 68 percent. Using higher concentrations of antifreeze will raise the freezing point of the solution and increase the possibility of a silica gel problem.

Legend 1 Freezing Point Temperature Scale 2 Boiling Point Temperature Scale A refractometer must be used to measure the freezing point of the coolant accurately. Use Cummins Filtration™ refractometer, Part Number CC2800 or CC2806. Do not use a floating ball hydrometer. Floating ball hydrometers can give incorrect readings. Cooling System Sealing Additives Do not use sealing additives in the cooling system. The use of sealing additives will: Build up in coolant low-flow areas Plug the radiator and oil cooler Possibly damage the water pump seal.