Cummins — 4021389

Normal Starting Procedure B3.9, B4.5, B5.9 Industrial Page 1-4 Section 1 - Operating Instructions Jump Starting Batteries can emit explosive gases. To avoid personal injury, always ventilate the compartment before servicing the batteries. To avoid arcing, remove the negative (-) battery cable first and attach the negative(-) battery cable last. WARNING When using jumper cables to start the engine, make sure to connect the cables in parallel: Positive (+) to positive (+) and negative(-) to negative (-). When using an external electrical source to start the engine, turn the disconnect switch to the OFF position. Remove the key before attaching the jumper cables.

CAUTION To avoid damage to engine parts, do not connect jumper starting or battery charging cable to any fuel system or electronic component. CAUTION This illustration shows a typical parallel battery connection. This arrangement doubles the cranking amperage. NOTE: Always reference the relevant OEM literature for jump starting procedures. Failure to follow correct procedures can result in damage to the ECM and other electrical equipment. This illustration shows a typical series battery connection. This arrangement, positive (+) to negative (-), doubles the voltage. NOTE: Always reference the relevant OEM literature for jump starting procedures.

Failure to follow correct procedures can result in damage to the ECM and other electrical equipment.