Cummins — 4021389

B3.9, B4.5, B5.9 Industrial Operating the Engine Section 1 - Operating Instructions Page 1-7 Starting Procedure After Extended Shutdown or Oil Change General Information Complete the following steps after each oil change, or after the engine has been shut down for more than 30 days to make sure the engine receives the correct oil flow through the lubricating oil system. 1. Disconnect the electrical wire from the fuel pump solenoid. 2. Rotate the crankshaft, using the starting motor, until oil pressure appears on the gauge or the warning lamp goes out. 3. Connect the electrical wire to the fuel pump solenoid valve. 4. Start the engine. Refer to 101-014 (Normal Starting Procedure).

Operating the Engine Normal If equipped, monitor the oil pressure and coolant temperature gauges frequently. Refer to Lubricating Oil System specifications and Cooling System specifications, in Maintenance Specifications (Section V) for recommended operating pressures and temperatures. Shut off the engine if any pressure or temperature does not meet the specifications. Continuous operation with engine coolant temperature above or below the engine coolant temperature specifications listed in Maintenance Specifications (Section V) can damage the engine.

If an overheating condition starts to occur, reduce the power output of the engine by releasing the accelerator pedal or lever or shifting the transmission to a lower gear, or both, until the temperature returns to the normal operating range. If the engine temperature does not return to normal, shut off the engine, and refer to Troubleshooting Symptoms (Section TS), or contact a Cummins® Authorized Repair Location.