B3.9, B4.5, B5.9 Industrial Radiator Pressure Cap Section 4 - Maintenance Procedures at 250 Hours or 3 Months Page 4-5 Air in the coolant can result in loss of coolant from the overflow when the aerated coolant is hot. The heated air expands, increasing the pressure in the system, causing the cap to open. Similarly, coolant can be displaced through the overflow if the head gasket leaks compression gases to the coolant system. The operating pressure of the coolant system and the lubricating system can result in the mixing of the fluids if there is a leak between the systems, such as the head gasket or oil cooler (refer to Procedure 007-037 Lubricating Oil System in Section 7). NOTE:
Transmission fluid can also leak into the coolant through radiator bottom tank transmission oil coolers. Refer to the OEM service manual. Inspect for Reuse Be sure the correct radiator cap is being used. Refer to (Cooling System) in Section V - Specifications. Inspect the rubber seal of the pressure cap for damage. Inspect the radiator fill neck for cracks or other damage. Refer to the radiator manufacturer for instructions if the fill neck is damaged. Pressure Test The system is designed to use the pressure cap to prevent boiling of the coolant. Different caps are specified for the two recommended systems:
System Cap A-Normal-Duty 104°C [219°F] 103 kPa [15 psi] B-Light-Duty 99°C [210°F] 48 kPa [7 psi]