Doosan P086TI — Doosan P086TI User Manual

10. Maintenance of Major Components 10.1. Cooling System 10.1.1. General information This engine is water-cooling type. Heat from the combustion chamber and engine oil heat are cooled down by coolant and radiated to the outside, resulting in the normal operation of the engine. Looking into the cooling system, the water pumped up by the water pump circulates around the oil cooler through the water pipe to absorb the oil heat, and then flows through the water jacket of the cylinder block and water passage of the cylinder head to absorb the heat of the combustion chamber.

The water absorbing the oil heat and combustion chamber heat goes on to the thermostat through the water pipe, and circulates to the water pump if water temperature is lower than the vaive opening temperature on the thermostat, while circulating to the radiator at water temperature higher than the valve opening coolant is radiated to cool down temperature. At the radiator, the heat absorbed in the and the coolant recirculates to the water pump. Thermostart Cooling water pipe i i i Radiator Cylinder head Cylinder block Oil cooler ==! Water pump EQM40011 - f21 -