Before stopping the engine, gradually reduce the load, then gradually reduce the engine speed to 600~1000 r/min. To stop the engine from the main control panel, press the emergency stop button provided on the display monitor.(Refer figure 4.18) Figure 4.18 And to stop the engine from the remote monitor, push the stop button (Refer Fig. 4.19) Figure 4.19 After stopping the engine, turn off the power supply to the control panel. To shut down the engines on emergency, press the emergency stop button provided on the control panel OR press the fuel cut off lever on the fuel injection pump OR shut off the main fuel supply valve near to the main fuel tank.

4.3.8 Running in period The engine components are made of materials with different thermal expansion and stability. It should be gradually set to the normal engine operating temperature. First 60 hours of operation is considered as running in period. During this period, engine needs to be run with care at normal load (80 to 85% maximum). Aggressive operation and loading during running in will disturb thermal stability and leads to shortened engine life. 19