Komatsu — 4.8.1 WALK-AROUND INSPECTION

MAINTENANCE 4.8 EVERY 10 OPERATING HOURS OR DAILY Legend for illustration Z25475 (18) Check automatic lubrication systems for leakage, damaged hoses and connections. (19) Check housing of oil cooler fan bearing for leakage. Check fan guards and coverings for correct installation, good condition and security. (20) Check hydraulic oil cooler for plugged cores. (21) Check hydraulic oil level. Check hydraulic oil reservoir for leakage, dam- aged hoses and connections. (22) Check condition and fastening of control valves. (23) Check PTO and hydraulic pumps for leakage, damaged hoses and con- nections. (24) Check flexible coupling between engine and PTO for leakage.

(25) Check engine for good condition and security. Check for oil and fuel leak- ages. (26) Engine mounts, check for good condition and correct fastening. (27) Operator’s cab air conditioning and air filter, check hoses for leakages and loose connections. (28) Emergency escape ladder, check condition and fastening. If any damages, failures or wrong condition, have been found during the inspection, corrective action must be taken. 269 CAUTION CAUTION