Ditch Witch RT115 Tier 2 — Lube pivots every 10 hours with EPG.

10 HOUR SERVICE Check plow vibrator oil on each side of vibrator every 10 hours. With vibrator horizontal, oil should be halfway up sight glass (2). Add MPL as needed at fill (1). IMPORTANT: Do not add oil to plow vibrator when hot. Let plow vibrator cool before removing fill plug. 172 RT115 Tier 2 - SERVICE Lube pivots every 10 hours with EPG. p Check Plow Vibrator Oil Lube Plow Pivots Plow