Ditch Witch RT115 Tier 2 — Saw

50 HOUR SERVICE Drain oil at drain plug (2). Replace plug and move plow vibrator to horizontal position. Fill with MPL at fill (1) until oil is halfway up sight glass (2). Refill capacity is 4 qt (3.8 L). IMPORTANT: Do not drain oil from plow vibrator when hot. Let plow vibrator cool before removing drain plug. Wipe zerks clean and lube saw lift arm pivots every 50 hours with EPG. 182 RT115 Tier 2 - SERVICE Change plow vibrator oil after first 50 hours of operation. p Change Plow Vibrator Oil Lube Saw Lift Arm Pivot Plow Saw