Maintenance—Periodic Maintenance Footwell Removal 1. Park machine on level surface. 2. Remove any attachment. TX1066492A —UN—09APR10 3. Raise boom and lock in raised position. 4. Stop engine and engage park brake. 5. Raise and lock operator's station in up position. 6. Remove cap screws (1) from footwell (2). NOTE: For manual machines, ensure control lever boot is disengaged from footwell before removing. During installation, ensure the base of control lever boot snaps in groove of footwell. Right Side of Manual Machine Shown 7. Lift out footwell.
1— Cap Screw (6 used, 3 per side) 2— Footwell TX1066493A —UN—09APR10 OUT4001,00004FE -19-10NOV09-1/1 Fluid Analysis Program Test Kits and 3-Way Coolant Test Kit Fluid Analysis Program Test Kits and the 3-Way Coolant Test Kit are John Deere fluid sampling products to help you monitor machine maintenance and system condition. The objective of a fluid sampling program is to ensure machine availability when you need it and to reduce repair costs by identifying potential problems before they become critical. TX1003513A —UN—20FEB06 Engine, hydraulic, power train, and coolant samples should be taken from each system on a periodic basis, usually prior to a filter and/or fluid change interval.
Certain systems require more frequent sampling. Consult your authorized John Deere dealer on a maintenance program for your specific application. Your authorized John Deere dealer has the sampling products and expertise to assist you in lowering your overall operating costs through fluid sampling. Fluid Analysis Kits AM40430,00002FE -19-19OCT11-1/1 3-2-6 071713 PN=102