John Deere 326D, 328D, 332D — Take Fluid Samples

Maintenance—Every 500 Hours Check Chain Case Oil Level 1. Park machine. 2. Remove fill plugs (1) located on each side of the machine frame. TX1065752A —UN—08OCT09 3. Oil level should be just below fill plug threads. 4. If necessary, add oil. For recommended oil, see Chain Case Oil. (Section 3-1.) 5. Install fill plugs. 1— Fill Plug (2 used) Chain Case Fill Plug OUT4001,00004C7 -19-12NOV12-1/1 Take Fluid Samples Hydraulic Oil Diesel Fuel Coolant See your authorized dealer for taking the following fluid samples: OUT4001,00004CA -19-18DEC12-1/1 3-8-7 071713 PN=124