Miscellaneous—Machine Using Battery Charger CAUTION: Prevent possible injury from exploding battery. Do not charge a battery if the battery is frozen or it may explode. Warm battery to 16°C (60°F) before charging. TS204 —UN—15APR13 Turn off charger before connecting or disconnecting it. IMPORTANT: Do not use battery charger as a booster if a battery has a 1.150 specific gravity reading or lower. Disconnect battery ground (-) clamp before you charge batteries in the machine to prevent damage to electrical components. Prevent Battery Explosions A battery charger may be used as a booster to start engine. Ventilate the area where batteries are being charged.
Stop or cut back charging rate if battery case feels hot, or is venting electrolyte. Battery temperature must not exceed 52°C (125°F). N36890 —UN—07OCT88 Charger OUT4001,0000239 -19-03JAN12-1/1 Using Booster Batteries—12-Volt System Before boost starting, machine must be properly shut down to prevent unexpected machine movement when engine starts. CAUTION: Prevent possible injury from exploding battery. An explosive gas is produced while batteries are in use or being charged. Keep flames or sparks away from the battery area. Make sure the batteries are charged in a well ventilated area. TS204 —UN—15APR13 IMPORTANT: The machine electrical system is a 12-volt negative (-) ground.
Use only 12-volt booster batteries. Using Booster Batteries 1. Connect one end of the positive cable to the positive terminal of the machine batteries and the other end to the positive terminal of the booster batteries. 3. Start engine. 4. Immediately after starting engine disconnect end of the negative cable from the machine. Then disconnect the other end of the negative cable from the negative terminal of the booster batteries. 2. Connect one end of the negative cable to the negative terminal of the booster batteries. Connect other end of the negative cable to the machine as far away from the machine batteries as possible. 5.
Disconnect positive cable from booster batteries and machine batteries. OUT4001,00000E1 -19-12JUL13-1/1 4-1-5 071713 PN=136