Miscellaneous—Machine Welding On Machine weld area so electrical current does not pass through any bearings. IMPORTANT: Disconnect both negative and positive battery cables and microprocessor unit (if applicable). Remove or protect all parts that can be damaged by heat or weld splatter. Have only a qualified welder do this job. Connect welder ground clamp close to each VD76477,00004EE -19-31OCT12-1/1 Welding Near Electronic Control Units IMPORTANT: Do not jump-start engines with arc welding equipment. Currents and voltages are too high and may cause permanent damage. 1. Disconnect the negative (-) battery cable(s). 2. Disconnect the positive (+) battery cable(s). TS953 —UN—15MAY90 3.
Connect the positive and negative cables together. Do not attach to vehicle frame. 4. Clear or move any wiring harness sections away from welding area. 5. Connect welder ground close to welding point and away from control units. 6. After welding, reverse Steps 1—5. DX,WW,ECU02 -19-14AUG09-1/1 Keep Electronic Control Unit Connectors Clean 2. If a connector is not in use, put on the proper dust cap or an appropriate seal to protect it from foreign debris and moisture. IMPORTANT: Do not open control unit and do not clean with a high-pressure spray. Moisture, dirt, and other contaminants may cause permanent damage. 3. Control units are not repairable. 4.
Since control units are the components LEAST likely to fail, isolate failure before replacing by completing a diagnostic procedure. (See your John Deere dealer.) 1. Keep terminals clean and free of foreign debris. Moisture, dirt, and other contaminants may cause the terminals to erode over time and not make a good electrical connection. 5. The wiring harness terminals and connectors for electronic control units are repairable. DX,WW,ECU04 -19-11JUN09-1/1 4-1-7 071713 PN=138