. MAINTENANCE SERVICE PROCEDURE EVERY 4000 HOURS SERVICE REPLACE ACCUMULATOR (FOR CONTROL CIRCUIT) WARNING If operations are continued after the performance of the accumulator has dropped, it will be remaining pressure in the hydraulic failure on the machine. Please ask your Komatsu distributor to replace the accumulator. 4 - 70 Maintenance for every 250, 500, 1000 and 2000 hours service s hould be c arried out at the s The accumulator i s charged with high-press ure nitrogen g as, so m istake n operation may cause an explo sion, which will l ead to serious injury or d amage. When handling th e accumulator , always do as follows.
The pressure i n the hydraulic circuit can not be completely removed. When removing the hydraulic e quipment, do not stand in the direction the operation. that the oil spurts out wh en carrying out the operation. In addition , loosen the bolts sl owly when carrying out mble the accumulator. near flame or dispose of it in fire. oles in it or weld it. ll it, or subject it to any impact. Do not disasse Do not bring it near flame or dispose of i Do not make h oles in it or weld it. Do not hit it, ro ll it, or subject it to any im When disposin g of the accumulator, the gas must be r eleased . Pleas e contact y our Komatsu distri butor to have this work carried out.
impossibl e to relea ircuit if there shoul d be CHECK WATER PUMP Check for oil an d coolant leakage, or cl ogging of the drain h ole. If any abnormality is found, c ontact your Komatsu distributor for di sassembly, repair, or re placement. CHECK INJECT OR See Section "B REGULATION AREA ( PAGE 4-18)" REPLACE INJECTOR ASSEMBLY See Section "A REGULATION AREA ( PAGE 4-18)"