Caterpillar C7 ACERT, C9 ACERT, C11 ACERT, C13 ACERT, C15 ACERT, C18 ACERT, C27 ACERT, C32 ACERT — Caterpillar C7 ACERT, C9 ACERT, C11 ACERT, C13 ACERT, C15 ACERT, C18 ACERT, C27 ACERT, C32 ACERT User Manual

Engine Monitoring and Protection 15.1.6.2 Fuel Temperature Monitoring Configuration Three parameters can be configured in Cat ET to customize the monitoring system for fuel temperature monitoring. 1. ECU action for an event code defaults to “On” for Warning and Derate and “Off” for Shutdown. All actions can be configured to “On” or “Off.” 2. Time delay to take action defaults to 30 seconds for Warning and 10 seconds for Derate and Shutdown. The time delay to take action on high fuel temperature event can be set within the range specified in the configuration table below. 3. Fuel temperature maximum limit default for Warning is 90 C° and for Derate and Shutdown is 91 C°.

The maximum temperature limit can be lowered within the range specified in the configuration table below. The following table summarizes the configuration default settings and configuration ranges for high fuel temperature monitoring: NOTE: Cat ET may allow the Derate Set Point Range to be programmed even though the chart above indicates that it is Not Programmable. If the set point in Cat ET is altered, this will only change the temperature at which an Event Code is logged. The programmed value will NOT change the temperatures at which the engine actually takes action to Derate. NOTE:

Engine must be running at engine speeds at or above low idle for 180 seconds before the above time delay is triggered. 15.1.6.3 Fuel Temperature Monitoring Installation No installation is required for fuel temperature monitoring to function. 15.1.7 Fuel Pressure 15.1.7.1 Fuel Pressure Monitoring Operation C7 ACERT-C32 ACERT engines have a fuel pressure sensor included in the standard sensor package. Fuel pressure is monitored to automatically protect the engine from exceeding a maximum fuel pressure limit. The fuel pressure measured by the ECU is compared to a maximum fuel pressure limit configured in the monitoring system for fuel pressure monitoring.

If the fuel pressure is above the maximum fuel pressure for the specified warning delay time, then the ECU takes the appropriate action to respond to the fault condition. Once the fault is detected, the ECU illuminates the warning and diagnostic lamps and logs the appropriate event code from the following table for the action taken:

A P P L I C A T I O N A N D I N S T A L L A T I O N G U I D E 101 HIGH FUEL TEMPERATURE MONITORING CONFIGURATION Action Default Value Time Delay (sec) Set Points Range Default Range Default Warning On 1 to 120s 30 70° C to 90° C 90° C Derate On 1 to 120s 10 Not Programmable 91° C Shutdown Off 1 to 120s 10 71° C to 91° C Cat ET Description J1939 Description Status SPN FMI High Fuel Pressure Fuel Delivery Pressure Warning 94 15