Caterpillar C7 ACERT, C9 ACERT, C11 ACERT, C13 ACERT, C15 ACERT, C18 ACERT, C27 ACERT, C32 ACERT — Caterpillar C7 ACERT, C9 ACERT, C11 ACERT, C13 ACERT, C15 ACERT, C18 ACERT, C27 ACERT, C32 ACERT User Manual

Engine Monitoring and Protection 15.3.1.3 Overspeed Verify Switch Installation P1/J1 ECU Negative Battery (1) Cut to length 15.4 Engine Maintenance Indicator 15.4.1 Maintenance Indicator Operation The ECU records data that is related to equipment maintenance. The ECU will activate the maintenance indicator lamp when scheduled maintenance is due. The maintenance indicator lamp is reset when the maintenance clear switch is closed to ground. The maintenance interval can be based on operating hours or on fuel consumption. The ECU provides information that pertains to maintenance intervals and the last maintenance that was performed.

15.4.2 Maintenance Indicator Mode Configuration Two parameters must be configured in Cat ET prior to using the maintenance lamp and maintenance clear switch. 1. “Maintenance Indicator Mode” defaults to OFF; it can be set to: a. OFF b. Auto Fuel c. Auto Hour d. Man Fuel e. Man Hour 2. “PM1 Interval” defaults to 250 hours; it can be set to: a. 100 to 750 hours b. 3785 to 28390 L (1000 to 7500 US gal) NOTE: If Maintenance Indicator Mode is set to Auto Fuel or Auto Hours, then PM1 Interval does not apply. I N D U S T R I A L E N G I N E E L E C T R O N I C S 108 54 Overspeed Verify Switch REQUIRED PARTS Part Number Description Qty 9X-3402 Connector Socket 1 N/A Switch 1 N/A 18 AWG Wire (ECU) (1)