Data Link Support The industrial engine control system supports the parameter group numbers (PGN) listed in the following table:
I N D U S T R I A L E N G I N E E L E C T R O N I C S 126 Parameter Group PGN SPN Parameters Supported Dec Hex Torque/Speed Control 1 (TSC1) 0 0000 695 Engine Override Control Mode 898 Engine Requested Speed/Speed Limit 518 Requested Torque/Torque Limit 897 Override Control Mode Priority Electronic Transmission Controller 1 (ETC1) 61442 F002 191 Transmission Output Shaft Speed Electronic Engine Control 2 (EEC2) 61443 F003 91 Accelerator Pedal Position 1 92 Engine Percent Load at Current Speed Electronic Engine Control 1 (EEC1) 61444 F004 513 Actual Engine — Percent Torque 190 Engine Speed Auxiliary Analog Information 65164 FE8C 441 Auxiliary Temperature #1 1387 Auxiliary Pressure #1 Electronic Engine Control 3 (EEC3) 65247 FEDF 515 Engine’s Desired Operating Speed Shutdown 65252 FEE4 1081 Wait-to-Start Lamp Engine Hours/Revolutions 65253 FEE5 247 Engine Total Hours of Operation Fuel Consumption 65257 FEE9 250 Engine Total Fuel Used Engine Temperature 65262 FEEE 110 Engine Coolant Temperature 174 Engine Fuel Temperature Engine Fluid Level/Pressure 65263 FEEF 94 Engine Fuel Delivery Pressure 100 Engine Oil Pressure 111 Engine Coolant Level Fuel Economy (Liquid) 65266 FEF2 183 Engine Fuel Rate Inlet/Exhaust Conditions 65270 FEF6 102 Engine Turbocharger Boost Pressure 105 Engine Intake Manifold 1 Temperature Vehicle Electrical Power 65271 FEF7 168 Electrical Potential (Voltage) 158 Battery Potential (Voltage), Switched