Caterpillar C7 ACERT, C9 ACERT, C11 ACERT, C13 ACERT, C15 ACERT, C18 ACERT, C27 ACERT, C32 ACERT — Caterpillar C7 ACERT, C9 ACERT, C11 ACERT, C13 ACERT, C15 ACERT, C18 ACERT, C27 ACERT, C32 ACERT User Manual

Data Link Support Auxiliary Engine Shutdown Switch — This PGN is supported in industrial engine software released November 2007 and later (see the software availability chart in Section 9.3.1. The engine ECU will accept the status 01 to shut down (disable fuel injection) from any source on the data link. The requesting device should broadcast the shutdown message at a one-second interval until the engine comes to rest completely. 18.1.2.3 Electronic Transmission Controller 1 (ETC1): PGN 61442 Three cases are possible: 1. A transmission is present:

If a transmission ECU (Source 3) is present on the CAN and it has sent an ETC1 message, then loss of the ETC1 message from the transmission address will result in a diagnostic from the engine ECU for loss of transmission data link. 2. A transmission is present: If a transmission is present on the CAN, but does not ever send an ETC1 message, then there is no diagnostic for the loss of transmission data link. 3. No transmission is present: If no transmission and therefore no transmission ECU is present, then an ETC1 message will not be sent, and there is no diagnostic for the loss of transmission data link.

I N D U S T R I A L E N G I N E E L E C T R O N I C S 130 Identifier Rate (msec) PGN Default Priority DP Source Destination 0C F0 02 03 10 F002 3 0 3 — Send Receive Subgroup Name SPN Byte Bit Length State Units Resolution (unit/bit) Range Min Max Transmission Driveline Engaged 560 1 1 2 binary 00b 11b Torque Converter Lockup Engaged 573 1 3 2 binary 00b 01b Transmission Shift in Process 574 1 5 2 binary 00b 01b Not Defined — 1 7 2 X Transmission Output Shaft Speed 191 2-3 16 rpm 0.125 0 8031 Percent Clutch Slip 522 4 8 % 0.4 0 100 Engine Momentary Overspeed Enabled 606 5 1 2 binary 00b 11b Progressive Shift Disabled 607 5 3 2 binary 00b 11b Not Defined — 5 5 4 Transmission Input Shaft Speed 161 6-7 16 rpm 0.125 0 8031 Source Address of Controlling Device for Transmission Control 1482 8 8 none 1 0 250