Data Link Support 18.1.2.5 Electronic Engine Controller 1 (EEC1): PGN 61444 Broadcast Rate — The J1939 standard describes the frequency of transmission of this PGN as engine speed dependent. The ECU actually transmits the message every 15 ms irrespective of engine speed. Engine Speed — Actual engine speed is set to 0 rpm when there is a fault detected with speed sensor measurement instead of EF00 as defined in standard. This avoids issues on engine crank with controls that do not correctly interpret the error code.

I N D U S T R I A L E N G I N E E L E C T R O N I C S 132 Identifier Rate (msec) PGN Default Priority DP Source Destination 0C F0 04 00 15 F004 3 0 00 — Send Receive Subgroup Name SPN Byte Bit Length State Units Resolution (unit/bit) Range Min Max Engine Torque Mode 899 1 1 4 binary 0000b 1110b Not Defined — 1 5 4 Drivers Demand Engine — Percent Torque 512 2 8 % 1 -125 125 X Actual Engine — Percent Torque 513 3 8 % 1 -125 125 X Engine Speed 190 4-5 16 rpm 0.125 0 8031 Source Address of Controlling Device for Engine Control 1483 6 8 none 1 0 253 Engine Starter Mode 1675 7 1 4 binary 0000b 1111b Not Defined — 7 5 4 Engine Demand — Percent Torque 2432 8 8 % 1 -125 125