Data Link Support Wait-to-Start Lamp — Intake air heater control strategy determines the status of the wait-to-start lamp parameter. The status is set to “ON” when the intake air heater strategy is in preheat mode during which the engine speed should remain at 0 rpm. 18.1.2.9 Engine Hours/Revolutions: PGN 65253 The SAE standard defines this PGN as send “on request.” There are some gauges and displays on the market which require this to be broadcast to display correctly, thus the engine control system will broadcast at a low update rate (1 sec) to ensure compatibility with these devices. 18.1.2.10 Fuel Consumption: PGN 65257 Total Fuel Used — This parameter is not a direct measurement.
It is an estimation based on standard test fuel at standard test temperatures. It is recommended, therefore, that this value be taken as an indication only of the fuel used by an engine.
A P P L I C A T I O N A N D I N S T A L L A T I O N G U I D E 135 Identifier Rate (msec) PGN Default Priority DP Source Destination 18 FE E5 00 1000 FEE5 6 0 00 — Send Receive Subgroup Name SPN Byte Bit Length State Units Resolution (unit/bit) Range Min Max X Engine Total Hours of Operation 247 1-4 32 hr 0.05 0 210,554,060 Engine Total Revolutions 249 5-8 32 rev 1000 0 4,211,081,215,000 Identifier Rate (msec) PGN Default Priority DP Source Destination 18 FE E9 00 On Req FEE9 6 0 00 — Send Receive Subgroup Name SPN Byte Bit Length State Units Resolution (unit/bit) Range Min Max Engine Trip Fuel 182 1-4 1 32 L 0.5 0 2,105,540,607 X Engine Total Fuel Used 250 5-8 1 32 L 0.5 0 2,105,540,607