Appendix A Appendix Appendix A.1 ECU Interface Requirements A 1.1 PWM Input The PWM input measures the frequency and duty cycle of a 500 Hz PWM signal. The input is a single-ended digital input. The signal input is to switch between 0 VDC (max 1.0 VDC) low state and 5 VDC (min 3.75 VDC, max 24 VDC) high state. The normal operating range for the 500 Hz PWM signal duty cycle is 5% to 95% and frequency is 150 Hz to 1000 Hz. Signal operation outside of this range will result in an abnormal signal diagnostic code on the ECU. Connection of the PWM signal to the ECU should be through wire size of #16 to #18 AWG with a wire specification that meets SAE J1128 for low-tension primary cable, type SXL.

Reference Connectors and Wiring Harness Requirements section for more information on wire selection. A 1.2 Switch to Ground Input The information in this section is general knowledge for connecting switches to the ECU switch to ground input. Specific information for a particular switch is located with the engine feature to which the switch belongs. Switch to ground inputs on the ECU are all pulled up to an internal power supply. A 1.2.1 Measuring Voltage in Switch Circuits Voltage that is supplied from the ECU to the switches will not normally exceed 13 VDC, regardless of the system voltage.

When any of the switch contacts are closed, the voltage drop through the switch circuit must be less than 1.4 VDC. This measurement should be taken at the ECU pin that supplies the switch and at the negative battery input to the ECU. This measurement includes the following values: • Ground Potential Differences • Voltage Drop Across the Switch • Voltage Drop Across the Wiring Harness When a switch contact is opened or the wiring harness has an open circuit, the internal pull-up voltages of the ECU force the respective input to 13 VDC.

Closing an OEM-installed switch must short circuit the switch input to the negative battery ground stud that is located near the ECU customer connector (J1/P1). Refer to the Power and Grounding Considerations section of this publication. I N D U S T R I A L E N G I N E E L E C T R O N I C S 146