Appendix A 1.4 Low-Side Current Driver (300 mA) Output The low-side ECU driver provides a path to the negative battery terminal in order to activate the device (lamp, etc.) that is connected to the circuit. While circuit protection is recommended for the lamp driver circuit, Caterpillar does not require dedicated circuit protection. When the ECU turns the driver on, the output pin will be within about 1 volt of the ECU negative battery terminal. The driver is designed to sink 300 mA over the ECU operating temperature range. The maximum leakage current with the driver off is 1 mA.
The driver will sink more than 300 mA briefly to handle “in-rush” situations such as turning on incandescent lights. Resistances for incandescent lamps or other dynamic devices are typically 10 percent of the steady state value for up to 150 ms when current is limited to 300 mA. Under these conditions, the driver shall not pulse on and off or current limit until the load reaches steady state resistance. The ECU is capable of detecting if continuous current exceeds 300 mA. The driver must never be expected to sink more than 300 mA continuous current. The driver will turn off automatically when a “load dump” is present and will turn back on when the “load dump” has dissipated.
Any load connected to the driver should be able to withstand “load dumps.” The lamps are to be connected to battery (+) to provide power to drive the lamps on. If the driver is connected to a discrete load (lamp, buzzer, etc.) the battery (+) connection for the load should be switched. Avoid having battery (+) connected to the load while the ECU is off. Connection of the low-side driver to the ECU should be through wire size of #16 to #18 AWG with a wire specification to meet SAE J1128 for low-tension primary cable, type SXL. Reference Connectors and Wiring Harness Requirements section for more information on wire selection. A P P L I C A T I O N A N D I N S T A L L A T I O N G U I D E 149