Caterpillar C7 ACERT, C9 ACERT, C11 ACERT, C13 ACERT, C15 ACERT, C18 ACERT, C27 ACERT, C32 ACERT — Caterpillar C7 ACERT, C9 ACERT, C11 ACERT, C13 ACERT, C15 ACERT, C18 ACERT, C27 ACERT, C32 ACERT User Manual

Appendix A 7 Switch Specifications The OEM supplies all switches. All switches that are provided by the OEM and connected to the Electronic Control Unit (ECU) must be of a two-wire design. These switches must be externally connected to the negative battery ground stud. Do not use switches that are grounded internally to the case. Momentary opening or closing of the switches and contact chatter should not exceed 100 milliseconds in duration. Vibration or shock that is normally found in the application should not cause opening or closing of the switches. The plating on the contacts should not be susceptible to corrosion or oxidation. Gold-plated switch contacts are recommended.

If a problem occurs with an undetermined cause, connect Cat ET and observe the status of the switch. Refer to the appropriate troubleshooting service manual for your engine. A 8 Installation Checklist Following is a checklist of installation design parameters that result in the majority of start-up issues if not implemented correctly. Use this as a guide when reviewing installation design with the customer or OEM: Battery Connections - Are all battery + and - leads connected to the ECU? - Is circuit protection adequate (i.e., correct number of circuit breakers that are sized appropriately)? - Is circuit protection in an easily accessible location? Is the engine grounded appropriately?

- Are all ground wires appropriately sized? - Has any paint or debris been removed at ground stud locations to facilitate grounding? Do all relays and solenoids have adequate noise suppression (i.e., flyback diodes)? Is the starting system sized appropriately to crank the engine to the minimum required starting speed under anticipated parasitic load conditions and anticipated temperature extremes? • Are all configuration parameters configured correctly? - Are throttles appropriately configured and calibrated? Note: Failure to properly set throttle input duty cycle will cause:

• Failure to reach low idle • Failure to reach high idle • Failure to reach full power • Failure to activate compression brake - Have configuration parameters been downloaded to a PC and saved? Printed and filed? Written down for future reference? Is the Monitoring System configured appropriately for the application? Will this application require operation at high altitude or low altitude? If so, contact your application support engineer. A P P L I C A T I O N A N D I N S T A L L A T I O N G U I D E 155