Caterpillar C7 ACERT, C9 ACERT, C11 ACERT, C13 ACERT, C15 ACERT, C18 ACERT, C27 ACERT, C32 ACERT — Caterpillar C7 ACERT, C9 ACERT, C11 ACERT, C13 ACERT, C15 ACERT, C18 ACERT, C27 ACERT, C32 ACERT User Manual

Customer Equipment I.D. and Passwords 6.3 Parameter Lockout 6.3.1 Parameter Lockout Operation Parameter Lockout changes the protection level of certain parameters from normal Cat ET access to factory password required. If customer passwords are programmed, these will also be required to lock an unlocked parameter in the Parameter Lockout Cat ET screen. The following configuration parameters can be selected to be locked out: • High Idle Speed • Rating Number • Top Engine Limit • Maximum Engine Torque Limit • Intermediate Engine Speed • Low Idle Speed • Programmable Monitoring System 6.3.2 Parameter Lockout Configuration Access the Parameter Lockout screen in the service menu of Cat ET.

Customer passwords are required to access this screen if programmed. One or more of the listed configuration parameters can be locked or unlocked in one session. All parameters default to unlocked. If a locked out parameter must be changed, there are two options: 1.Remove the lockout — In the Parameter Lockout screen, a factory password allows the protection level to be changed back to normal ET access. 2.Retain the lockout — In the Configuration screen, a factory password allows changing the value one time. A P P L I C A T I O N A N D I N S T A L L A T I O N G U I D E 41