Exhaust and Compression Brakes 10.2.3.2 Overspeed Protection Mode Configuration Two parameters must be configured in Cat ET prior to operating in overspeed protection mode. 1. Exhaust Valve Actuation System Installation Status defaults to “uninstalled” and must be set to “installed.” 2. Overspeed Trip Speed defaults to 2800 rpm and can be programmed between high idle and PMS max overspeed trip point. 10.2.4 Exhaust Brake Installation The ECU will source 2.0 amps to drive the exhaust brake relay at normal operating conditions. At cold operating conditions, the ECU may source as low as 1.0 amp to the relay.
If a third-party relay is used, select a relay that will operate between 1.0 A and 2.0 A. Positive Battery RETARDER LAMP Exhust Brake Relay Exhaust Brake Solenoid P1/J1 ECU Exhaust Brake Switch Input Negative Battery I N D U S T R I A L E N G I N E E L E C T R O N I C S 58 31 13 67 40 5 RETARDER LAMP EXHAUST BRAKE DRIVER SOLENOID COMMON EXHUAST BRAKE ENABLE DIGITAL SENSOR RETURN