Engine Speed Demand 11.1.3 TPS Installation Battery Positive Throttle Position Sensor J403/P403 Battery (+) Battery (-) P1/J1 ECU Signal Negative Battery 11.2 Dual Throttle Position Sensors Dual throttle is not available at this time. 11.3 Remote Speed Control 11.3.1 Remote Speed Control Operation The 140-2175 Remote Speed Control can be used to provide a pulse width modulated (PWM) signal to the ECU to control engine speed. Refer to section 11.1.1 for an explanation of PWM signals. The duty cycle of the PWM signal output can be adjusted by the use of a 1k potentiometer in Local Mode control or a 4-20mA current loop signal from a programmable logic controller (PLC) in Remote Mode control.

An input labeled LOCAL/RMTE on the Remote Speed Control enables the operator to switch between Local Mode and Remote Mode control provided that the change does not result in a change on the inputs that is greater than 2.5%. When the LOCAL/RMTE input is connected to negative battery through a switch, the Remote Speed Control is in Remote Mode. When the LOCAL/RMTE input is open, the Remote Speed Control is in Local Mode. When the Remote Speed Control is in Local Mode, adjusting the1k potentiometer, connected as shown in section 11.3.3, may result in a PWM duty cycle that is less than 5% or greater than 95%.

As discussed in section 11.1.1, when duty cycle values are less than 5% or greater than 95% the desired engine speed is set to low idle and a diagnostic code will be logged. Care should be taken when adjusting the potentiometer while the engine is running to avoid large changes in desired engine speed if and when the diagnostic threshold is crossed. When the Remote Speed Control is in Remote Mode, the duty cycle of the PWM signal will range between 8% ± 2% at 4mA from the PLC to 92% ± 2% at 20mA from the PLC. The same two programmable parameters used for configuring the TPS set-up can be used to configure the Remote Speed Control set-up.

These two parameters are the Throttle Input High Idle Duty Cycle and the Throttle Input Low Idle Duty Cycle. • When the ECU receives a PWM signal from the Remote Speed Control less than or equal to the programmed value for throttle input low idle duty cycle, the engine will govern speed at the programmed value for low idle. • When the ECU receives a PWM signal from the Remote Speed Control greater than or equal to throttle input high idle duty cycle, the engine will go to full engine speed as dictated by Top Engine Limit (TEL) and high idle programmable parameters. I N D U S T R I A L E N G I N E E L E C T R O N I C S 62 A B C 66 Throttle Position Sensor