Caterpillar C7 ACERT, C9 ACERT, C11 ACERT, C13 ACERT, C15 ACERT, C18 ACERT, C27 ACERT, C32 ACERT — Caterpillar C7 ACERT, C9 ACERT, C11 ACERT, C13 ACERT, C15 ACERT, C18 ACERT, C27 ACERT, C32 ACERT User Manual

Engine Speed Demand 11.4 9X9591 PWM Converter 11.4.1 9X9591 PWM Converter Operation The 9X9591 PWM Converter can be used to provide a Pulse Width Modulated (PWM) signal to the ECU to control engine speed. Refer to section 11.1.1 for an explanation of PWM signals. This control can produce two separate PWM signals. One PWM signal duty cycle is control by an external potentiometer, the other PWM signal duty cycle is controlled by an internal potentiometer. The most common wiring configuration is shown in the graphic in section 11.4.3. An external potentiometer is connected to terminals 1, 2, and 3, with the wiper of the potentiometer connected to terminal 2.

The resistance value of the potentiometer must be 1k or greater. The adjustment of the external potentiometer controls the duty cycle of the PWM signal on the output terminal S. The duty cycle on this terminal can be varied from 5 percent to 95 percent. The internal 2k potentiometer can be adjusted to vary the PWM duty cycle on terminal D. Some applications use this as a droop signal. The duty cycle on this terminal can be varied from 5 percent to 95 percent. The 9X9591 PWM Converter cannot be used on 12Vdc systems (supply voltage must be between 15Vdc and 45Vdc).

The same two programmable parameters used for configuring the TPS set-up can be used to configure the 9X9591 PWM Converter set-up. These two parameters are the Throttle Input High Idle Duty Cycle and the Throttle Input Low Idle Duty Cycle. • When the ECU receives a PWM signal from the 9X9591 PWM Converter less than or equal to the programmed value for throttle input low idle duty cycle, the engine will govern speed at the programmed value for low idle.

• When the ECU receives a PWM signal from the 9X9591 PWM Converter greater than or equal to throttle input high idle duty cycle, the engine will go to full engine speed as dictated by Top Engine Limit (TEL) and high idle programmable parameters. 11.4.2 9X9591 PWM Converter Configuration The same three parameters used for the TPS configuration in section 11.1.2 are used for the 9X9591 PWM Converter configuration. 1. The Throttle Position Sensor parameter must be programmed to “Installed.” 2.The Throttle Input Low Idle Duty Cycle parameter defaults to 10 and can be set from 10 to 40 (refer to the 9X9591 PWM Converter set-up procedure below to determine the proper settings).

3.The Throttle Input High Idle Duty Cycle parameter defaults to 90 and can be set from 50 to 90 (refer to the 9X9591 PWM Converter set-up procedure below to determine the proper settings). I N D U S T R I A L E N G I N E E L E C T R O N I C S 66