Caterpillar C7 ACERT, C9 ACERT, C11 ACERT, C13 ACERT, C15 ACERT, C18 ACERT, C27 ACERT, C32 ACERT — Caterpillar C7 ACERT, C9 ACERT, C11 ACERT, C13 ACERT, C15 ACERT, C18 ACERT, C27 ACERT, C32 ACERT User Manual

Engine Speed Demand 11.7.3 PTO Ramp Up/Down Mode Installation Refer to the PTO ramp up/ramp down switch status truth table (Table 4) for an overview of the PTO ramp up/ramp down operation for the different switch input state combinations. Following are general tips to consider when wiring to the switch inputs: • If PTO ramp up/ramp down is the only means of controlling engine speed, the PTO enable circuit may be wired directly to the battery negative. • P1/J1 Pin 56 or 58 may be switched to battery negative for extended periods of time if the method of control is simply to provide either high idle or low idle.

• If Pin 58 and 60 are both connected to ground at the same time the engine will maintain the current speed and will not allow speed changes until the PTO enable input, Pin 56, is cycled. Table 4:

PTO Ramp Up/Ramp Down Switch Status Truth Table PTO Enable Switch P1/J1 ECU Negative Battery PTO Ramp Up/Down Switch (1) Fabricated to length A P P L I C A T I O N A N D I N S T A L L A T I O N G U I D E 71 Switch Status Speed Demand Status PTO Enable Ramp Up Ramp Down Open Any Any Set to the valid throttle speed Close Open Open Remain at current desired engine speed Close Open Close Ramp down Close Close Open Ramp up Close Close Close Invalid combination — latch speed 56 58 60 PTO Enable Switch Ramp Up Switch Ramp Down Switch REQUIRED PARTS Part Number Description Qty N/A Toggle Switch (SPST) 1 N/A Toggle Switch (SPDT Momentary) 1 9X-3402 Connector Socket 3 N/A Terminal 5 N/A 18 AWG Wire (1)