Engine Governor 13.1 Full Range Engine Speed Governor 13.1.1 Full Range Engine Speed Governor Operation The Full Range Engine Speed Governor will attempt to hold a constant engine speed for a given throttle position. The Full Range Engine Speed Governor senses engine speed, and perhaps load, and meters the fuel supply to the engine such that speed tends to remain constant or to vary with the load in a predetermined manner. This governor type is recommended for use on applications with constant operating speed (i.e. pumps, compressors, hydrostatic drives, etc.) and applications with manual transmissions.

The Full Range Engine Speed Governor is also known as a “variable speed” or “all speed” governor. The Full Range Engine Speed Governor control strategy calculates the fuel quantity required to keep the actual engine speed equal to a desired engine speed. The desired engine speed is the output of the throttle arbitration strategy defined in the Engine Speed Demand section. The term “full range” is used because the desired engine speed range used by the control strategy covers the “full” engine operating speed range. The governor strategy has control parameters, commonly referred to as governor gains, which determine the response and stability of the engine.

The governor gains are “tuned” by Caterpillar in a lab environment for optimum engine performance under steady state and transient operating conditions. The Full Range Engine Speed Governor used on all industrial engines to date is an isochronous (or zero droop) speed governor. Figure 1 illustrates the isochronous speed governor operation across the engine operating speed range. The curve is bounded by the rating torque curve between LI and TEL engine speeds and the HSG limit curve above TEL engine speed. The vertical lines are engine torque output for a constant throttle position, or constant engine speed demand.

Thus, for a fixed throttle position below TEL engine speed, the speed governor will hold engine speed constant until the torque output reaches the torque limit curve, then the engine speed will decrease with torque output at the limit of the rated torque curve. This is also referred to as the torque lug curve. Isochronous speed governing above the configured TEL speed is limited by the HSG limit curve. This region of operation is often referred to as the overrun region. The HSG limit curve is always below the rated torque curve. This curve is linear where the slope of the line is determined by the configured TEL and HI engine speeds.

Figure 2 illustrates two HSG limit curves with a common HI engine speed and two different TEL engine speed settings. This illustration shows that the torque output with TEL 1 setting is limited at a lower torque than the TEL 2 setting. This also shows that speed governing is isochronous at all operating speeds in the overrun region. The different TEL settings will affect the engine response and stability under varying loads in this speed operating range. A P P L I C A T I O N A N D I N S T A L L A T I O N G U I D E 81