Engine Monitoring and Protection The timing for when the ECU takes action is based on set point and time delay settings. A set point and time delay is defined for each monitored parameter action level available for a monitored parameter. The set point is the lower (or upper) limit of a monitored parameter’s normal operating range. The delay time is how long the monitored parameter must exceed the set point before the ECU will take the programmed action (warning, derate, or shutdown). Not all set points and delay times can be configured for each monitored parameter. The action level, set point, and time delay settings are configured in the Monitoring System Configuration screen in Cat ET.
The customer does not have the option to change some of the monitoring system settings for certain monitored parameters. The parameter settings that cannot be configured will default to the setting programmed in the factory. See the subsections within Engine Monitoring and Protection section for each of the monitored parameters for more information on configuring the monitoring system. The following actions are taken by the ECU when a warning, derate, or shutdown condition is detected:
• ECU logs an event code • Event code information is broadcast on the J1939 CAN data link • Event code is available for display on Cat ET • Warning lamp is turned “ON” • Diagnostic lamp is turned “ON” (only event codes with flash codes) • ECU performs specified derate or shutdown action The monitoring system will reduce rated power when derate or shutdown action is specified. The rated power is reduced as a percentage from the rated power at a given engine speed. The percent derate can be a percentage drop from the rated power curve or a percent reduction towards a default power curve. When using a default curve, the default curve is typically set to 50 percent of the rated power curve.
Figure 6 illustrates the power derate using a default power curve. Figure 6: Torque Curve Derate Curve 1000 Rated Power Curve 800 600 400 Default Power Curve (50% Rated) 200 0 1000 1400 1800 2200 Engine Speed (rpm) The power rating is limited in a derate condition, so this does not affect performance unless the power demand is for rated power. In other words, if you have a 10 percent derate but you are only using 10 percent of the rated power, you will have no change in operation. I N D U S T R I A L E N G I N E E L E C T R O N I C S 92 45% Derate 100% Derate